what is ISO 20653 IP Code Testing?
From: BONAD  Date: 2024-04-02 15:02:05

ISO 20653 is a standard that specifies the degrees of protection provided by enclosures against the intrusion of solid objects (including dust) and water. It defines the IP (Ingress Protection) code, which consists of two digits. The first digit represents the level of protection against solid objects, and the second digit represents the level of protection against water.

IP code testing according to ISO 20653 involves subjecting the enclosure to various tests to assess its resistance to dust and water ingress. These tests include:

  1. Dust Testing: The enclosure is exposed to fine dust particles to determine its ability to prevent dust penetration. Different levels of dust concentration are used based on the intended application.

  2. Water Testing: The enclosure is subjected to various water flow rates and pressures to evaluate its resistance against water ingress. This includes tests for dripping water, spraying water, and immersion in water.

The results of these tests determine the IP code rating for the enclosure, indicating its level of protection against both solid objects and water. ISO 20653 IP code testing ensures that products meet specific requirements for different environments, such as outdoor or industrial settings, where protection against dust and water is crucial.


The remainder of this page outlines the different tests parameters located in the ISO 20653 standard:

Overview of All IP Code Elements and Meaning

Element

IP

Meaning of the protection of electrical equipment

Meaning of the protection of persons

First Code of Element

Against foreign objects (including dust):

Against Access:

0

Not protected

Not protected

1

With diameter > 50 mm

With back of hand

2

With diameter >12,5 mm

With finger

3

With diameter > 2,5 mm

With tool

4

With diameter > 1,0 mm

With wire

5K

Dust protected

With wire

6K

Dust tight

With wire

Second Code Element

Against water:

Not applicable

0

Not protected

1

Vertical water drips

2

Water drips (15 degrees inclination)

3

Water spray

4

Splash water

4K

Splash water with increased pressure

5

High-velocity water

6

Strong high-velocity water

6K

Strong high-velocity water with increased pressure

7

Temporary immersion

8

Continuous submersion

9K

High pressure/steam-jet cleaning

Additional Letter (optional)

Not applicable

Against access (unless described by first letter)

A

With back of hand

B

With finger

C

With tool

D

With wire

Supplementary Letter (optional)

M

Movement of moveable parts during water test

Not applicable

S

Standstill of moveable parts during water test

Degrees of Protection Against Foreign Objects

First code element

Degree of protection

Brief description

Requirements

0

Not protected

None

1

Foreign objects diameter ≥ 50 mm

Test probe with diameter 50 mm shall not penetrate completely

2

Foreign objects diameter ≥ 12,5 mm

Test probe with diameter 12,5 mm shall not penetrate completely

3

Foreign objects diameter ≥ 2,5 mm

Test probe with diameter 2,5 mm shall not penetrate completely

4

Foreign objects diameter ≥ 1,0 mm

Test probe with diameter 1,0 mm shall not penetrate completely

5K

Dust

Dust shall only penetrate in quantities which do not impair performance and safety.

6K

Dust

Dust shall not penetrate

NOTE “Shall not penetrate completely” indicates that the full diameter shall not pass through an opening of the enclosure.

Degrees of Protection Against Access

First code element

Additional letter

Degree of protection

Brief description

Requirements

0

Not protected

None

1

A

Back of hand (no protection against intentional contact)

Test probe with diameter 50 mm shall not penetrate completely and maintain sufficient distance from hazardous parts.

2

B

Finger

Jointed test finger with diameter 12 mm may penetrate completely, but shall maintain a sufficient distance from hazardous parts.

3

C

Tool

Test probe with diameter 2,5 mm, 100 mm long, may penetrate completely, but shall maintain a sufficient distance from hazardous parts.

4

D

Wire

Test probe with diameter 1,0 mm, 100 mm long, may penetrate completely, but shall maintain a sufficient distance

5K

D

Wire

6K

D

Wire

NOTE “Shall not penetrate completely” indicates that the full diameter shall not pass through an opening of the enclosure.

Degrees of protection against water

Second code element

Degree of protection

Brief description

Requirements

0

Not protected

None

1

Water drips vertically

Vertical drips shall not have any harmful effects or impair performance.

2

Water drips with enclosure inclined by 15°

Vertical drips shall not have any harmful effects or impair performance when the enclosure is tilted at any angle up to 15° on either side of the vertical.

3

Water spray

Water spray at an angle up to 60° on either side of the vertical shall have no harmful effects or impair performance.

4

Splash water

Water which splashes against the enclosure from any direction shall not have any harmful effects or impair performance.

4K

Splash water with increased pressure

Water which splashes against the enclosure from any direction with increased pressure shall not have any harmful effects or impair performance.

5

High-velocity water

Water which is directed against the enclosure from any direction as a jet shall not have any harmful effects or impair performance.

6

Strong high-velocity water

Water which is directed against the enclosure from any direction as a strong jet shall not have any harmful effects or impair performance.

6K

Strong high-velocity water with increased pressure

Water which is directed against the enclosure from any direction as a strong jet with increased pressure shall not have any harmful effects or impair performance.

7

Temporary immersion in water

Water shall not penetrate in a quantity causing harmful effects or impair performance if the enclosure is immersed in water temporarily under specified pressure and time conditions.

8

Continuous immersion in water

Water shall not penetrate in a quantity causing harmful effects if the enclosure is continuously immersed in water under conditions which shall be agreed between supplier and car manufacturer, but which are more severe than code 7.

9K

Water during high-pressure/steam-jet cleaning

Water which is directed against the enclosure from any direction shall not have any harmful effects or impair performance.




 
 
Home  |  Products  |  News  |  About us  |  Feedback  |  Contact us  |  
Copyright © 2008-2015 Hong Kong Bonad Technology Limited | Shenzhen Bonad Instrument Co., LTD. All Rights Reserved.
 
    Add:C505, Hongdu Building,Bao\\\'an45 district,Shenzhen,518101,Guangdong Province,China    Tel:+86-13380391156    Fax:0755-23721200    Email:Alice@szbonad.com
 
主站蜘蛛池模板: 亚洲日韩精品欧美一区二区一| A级毛片三个男人一女| 午夜精品无码一区二区三区| 精品丰满熟女一区二区三区| 一区、二区、三区仿佛是不同的舞台| 69视频在线免费观看| AV先锋女优天堂网| 亚洲欧美国产日韩中文丝袜| 欧美先锋资源| 午夜视频会员女优| 国产午夜精品福利久久| 成熟女人毛片WWW免费版在线| 亚洲,日本,欧美手机版三级片| 国产猛男猛女超爽免费视频| 四川一级护士一级毛片| 月亮与乳房| 又大又长粗又爽又黄少妇视频| 中文成人无字幕乱码精品区| 国产精品久久久久粉嫩小泬| 97人妻碰碰视频免费上线| 欧美久草蜜桃| 国产AV人人夜夜澡人人爽麻豆 | 色天使色婷婷丁香久久综合| 丰满人妻一区二区三区免费视频| 欧美一级尻穴视频| 午夜剧场av| A片无码毛片精品无码嫩草久色| 被老外添嫩苞添高潮np视频| 无码精品人妻一区二区三区人妻斩| 国产又爽又黄无码无遮挡在线观看| 黄色在线观看成人影视大全| 亚洲国产日韩在线观看| 欧美日韩在线亚洲综合国产人| 一区二区三区内射美女毛片| www.AV电影| 手机看片久久国产永久免费| 久久精品国产乱子伦| 久久99国产精品久久99果冻传媒| 免费一级毛片一级A片成人片不卡嫩草影视| 999国产精品欧美久久久久久| 中文字幕办公室人妻丝袜成熟乱|